Rebuilt Kodak/Carestream RA3000
 
 
Choose rapid, standard or extended processing with fingertip ease with this space-saving, medium-volume rapid-access film processor. process T-Mat RA films in less than 50 seconds (59-second drop time) with the RA cycle. This cycle delivers 35cm x 43 cm films read-to-read at the rate of 270 per hour.

Weight:Approximately 302 lbs. with processing tanks filled with solution; 260 lbs. empty
Electrical Requirements:120/208 V, 30 A, 60 Hz, 4 wires (single phase)
Water Requirements:Water temperature 40-80F. Incoming water supply must be a minimum of 5.5C (10F) below the developer temperature setpoint for correct control of the developer temperature. (25-65 psi)
Drain Requirements:One 3 inch floor drain. Maximum draining flow is 4 gallons (15 L) /minute. Use only chemically resistant, non-corrosive material.
Dryer Exhaust:It is recommended that the processor be connected to a building exhaust duct capable of providing a 0.04 inches (1.02 mm) of water, constant negative static pressure at the processor. The exhaust may also be vented directly outside
Testing:All rebuilt equipment is tested in-house for a minimum 36-hour period prior to shipment.
WarrantyOne year parts warranty

 

DESCRIPTION:
The rebuilt Kodak/Carestream RA3000 features the ability to program custom cycles for special needs. Its advanced design minimizes chemical and water use with reduced service time due to its self-diagnostic features.

All units include:

  • All rebuilt units are thoroughly inspected and components replaced as necessary to bring machine up to OEM standards.
Available Options:
  • Stand
  • Exhaust Fan Kit

Go here for site specifications.


Site developed and hosted by Our Computer Guy